Loading...
Loading...

Flashback Arrestor 85-10U

Flashback Arrestor 85-10U

Flashback arrestor, certified to EN 730-1 / ISO 5175, UL listed, for high-performance cutting machines – without temperature-sensitive cut-off valve [TV]

  • highest quality from the world market leader
  • safety elements: flame arrestor [FA], check valve [NV], filter on gas inlet
  • every arrestor 100% tested
  • 1.34 X 4.17 inches, 17.36 oz
  • acetylene max. 777 scfh (free flow-off)
  • fuel gases max. 8,295 scfh (free flow-off)
  • oxygen max. 10,942 scfh (free flow-off)

Product of WITT 

Download Datasheet

 

Loading...

Description

WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks in accordance with EN 730-1, ISO 5175, UL 1357/1358. Every Arrestor 100% tested.

The best Flashback Arrestors in the world

  • a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
  • a temperature-sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestor reaches a dangerous level
  • a spring-loaded check valve NV prevents slow or sudden reverse gas flow from forming explosive mixtures in the gas supply

Operation / Usage:

  • Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
  • WITT Flashback Arrestors may be mounted in any position/orientation
  • only one piece of equipment may be connected to a single Flashback Arrestor
  • the maximum ambient/working temperature is 158°F

Maintenance:

  • annual testing of the check valve, body leak-tightness and flow capacity is recommended
  • WITT is happy to supply special test equipment
  • Flashback Arrestors are only to be serviced by the manufacturer; the dirt filter may be replaced according to model by competent staff

Approvals

Company certified according to ISO 9001
Cleaned for Oxygen Service according to EIGA IGC Doc 13/12/E: Oxygen Pipeline and Piping Systems

 