Description
WITT non-return valves for reliable protection against dangerous reverse gas flow. Every non-return valve 100% tested.
Benefits:
- a spring-loaded non-return valve prevents a reverse flow of gases which could lead to unwanted gas mixtures
- low opening pressure approx. 250 mbar
- no leaks – using a spring-loaded valve assembly with elastomer sealing
- diverse applications – useful for many technical gases
- reduce installation costs – the spring-loaded valve is not affected by gravity and may be installed in any orientation
Operation / Usage:
- non-return valves are used to protect equipment and pipelines against dangerous reverse gas flow
- the maximum ambient/working temperature is 70 °C / 158 °F
Maintenance:
- annual testing of the non-return valve, body leak tightness and flow capacity is recommended
- WITT is happy to supply special test equipment
- non-return valves are only to be serviced by the manufacturer
Approvals
Company certified to ISO 9001 and PED 2014/68/EC Module H
CE-marked in accordance with PED 2014/68/EC
Cleaned for Oxygen Service according to EIGA IGC Doc 13/12/E: Oxygen Pipeline and Piping Systems