Description
WITT non-return valves for reliable protection against dangerous reverse gas flow. Flow-optimised valve system causes a very low-pressure drop at minimal noise emission. Every non-return valve 100% tested.
ULTRA 12 is based on ULTRA 10 and is customised according to the requirements of the customer – ideal for special requirements. A modular system which allows flexible material combinations for housing and sealings.
Combination possibilities
- housing available in brass, stainless steel or aluminium
- sealings of NBR, CR, FKM, EPDM, FFKM for example
- with or without dirt filter in gas inlet
Benefits
- precisely tailored design for special requirements. For example corrosive environments, acetylene, ultra-lightweight construction, temperatures above 70 °C / 158 °F
- a spring-loaded non-return valve prevents back-feeding of gases which could lead to unwanted gas mixtures
- low-pressure drop – using complex valve assembly with low opening pressures (approx. 4 mbar)
- stainless steel filter (100 μm) in the gas inlet protects the non-return valve against dirt contamination, extending the service life
- flow-optimised valve system for:
– ultra low-pressure drop
– minimal noise emission
- no leaks – using of a spring-loaded valve assembly with elastomer sealing
- in accordance to DIN EN ISO 5175-2
- available in brass, stainless steel or aluminium
- diverse applications – useful for many technical gases
- reduce installation costs – the spring-loaded valve is not affected by gravity and may be installed in any orientation
Operation / Usage
- non-return valves are used to protect equipment and pipelines against dangerous reverse gas flow.
- Use is possible for applications according to EN 746-2
- WITT non-return valves may be mounted in any position/orientation
Maintenance
- annual testing of the non-return valve and body leak tightness is recommended
- WITT is happy to supply special test equipment
- non-return valves are only to be serviced by the manufacturer
Approvals
Company certified according to ISO 9001
Cleaned for Oxygen Service according to EIGA IGC Doc 13/12/E: Oxygen Pipeline and Piping Systems